Outdoor unit VRV A One-Dimensional Cold - Model RXQ18BYM | Strong Cold Performance 171,000 Btu/h

Introduction of outdoor unit VRV A RXQ18BYM
Outdoor unit VRV Cold One - Dimensional A Models RXQ18BYM And the brand's premium products are the ones that come from the brand DaikinThe building is dedicated to commercial buildings, high-rise offices, commercial centers and large hotels cooling capacity strong up to 171,000Btu/h (~50kW) and use refrigerant R410a environmentally friendly, RXQ18BYM offers rapid, stable and power - efficient cooling.
Technical specifications Highlights RXQ18BYM
| Specification | Details |
|---|---|
| Model | RXQ18BYM |
| Type | Outdoor unit VRV A – Cold one - dimensionality |
| Cooling capacity | 171,000Btu/h (~50 kW) |
| Power input | 13.8 kW |
| Refrigerant | R410a |
| Dimensions (C x R x S) | 1,660 x 1,240 x 765 mm |
| Weight | 285 kg |
The outstanding advantages of outdoor unit VRV RXQ18BYM
1. High - efficiency – Energy savings
With cooling capacity up to 50kW but power consumption only 13.8kW, RXQ18BYM is the ideal choice for optimizing efficiency and operating cost savings for the enterprise.
2. Quiet, stable operation
Outdoor unit is designed with advanced noise reduction technology, which operates stably even under high temperature conditions, providing a quiet and pleasant space.
3. Compact Design – Flexible Installation
The neat size and moderate weight make the equipment easier to position in various locations, convenient for construction and maintenance.
4. Use of environmentally friendly R410a gas
Gas R410a has higher cooling efficiency and less harm to the ozone layer, contributing to environmental protection and compliance with global climate standards.
Application of outdoor unit VRV RXQ18BYM
Outdoor unit RXQ18BYM conforms to central air conditioning VRV/VRF systems installed for:
-
High - rise office building
-
Hotels, resorts
-
Shopping malls, supermarkets
-
Factories and workshops
-
School, hospital
Why choose RXQ18BYM for your work?
-
Superior cooling performance
-
Long - term operating cost savings
-
Long life, easy to maintain
-
Environment-friendly
-
Good response for large air conditioning systems
Consultant and quotation contacts RXQ18BYM
If you are looking for a professional, sustainable cooling solution for your building, contact us immediately detailed consultation, free survey and best quote cho outdoor unit VRV RXQ18BYM.
✅ 1. Preparation before installation
📌 Check the installation position
-
Location to ensure ventilated, It's not windblown and it's blowing out, maybe easy to maintain.
-
Do not install near steam, corrosive gas, or a fire-prone area.
-
Make sure the surface is flat and load - bearing ( ≥ 350kg).
-
Minimum distance:
-
In front of outdoor unit: ≥ 1,000mm
-
Rear, side: ≥ 300mm
-
Top: ≥ 500mm
-
Between outdoor unit: ≥ 100mm
-
Height difference between outdoor unit and indoor unit: in terms of Daikin limit (typically ≤ 50 m)
-
. 2. Construction of base and frame outdoor unit
🧱 Concrete base
-
Solesize: longer and wider than the base outdoor unit from 100 – 200mm.
-
Pour concrete M200, at least thick 150mm.
-
Insert the M12 or M14 wait bolts to fix outdoor unit.
🪵 Steel frame (in case of hanging or roof)
-
Use ≥ 5mm - bearing box/inox steel.
-
Fixed solder, rust - resistant 2 coating and top coat.
-
Check your nivo balance after you finish.
✅ 3. Installation and immobilization outdoor unit RXQ18BYM
-
Use a forklift or palang to lower the outdoor unit up into position.
-
Line the base with vibration - resistant rubber.
-
Squeeze the bolt firmly, but not so tight that it cracks the case.
-
Check the equilibrium outdoor unit with nivo.
✅ 4. Gas connection
🔧 Copper pipe technical requirements
-
Use copper tubing soft cast whole - plant (coil) meets JIS H3300 Mortality Type H standard.
-
The pipe diameter should be the manufacturer's design for the model RXQ18BYM (e.g., Ø 28.58mm or Ø 34.9mm depending on power).
🔧 Duct wiring technique
-
Use a flare and wrench to apply the force to the right torque Daikin.
-
Vacuum the entire system after the connection.
-
Check for leaks with a spray bottle or pressure gauge.
-
Sealable insulation and tape 100%.
✅ 5
⚡ Source Parameters
-
Power source: 3 phase ~ 380 V – 50 Hz
-
Capacity: 13.8kW
-
Rated current: refer to technical documentation Daikin
⚡ Outdoor Electrical Panel Installation
-
Electrical wires: negative chicken intubation/PVC pipe.
-
Use copper wire with a minimum load 10mm²).
-
Attach separate CBs to each outdoor unit.
-
Secure grounding <10 Ω (separate grounding if necessary).
✅ 6. Control signal connection (if any)
-
Use the control wire attached to indoor unit, the B/C center, or the central control (if applicable).
-
Make sure the polarity is correct (S1 – S2 – S3) and do not share the tube with the power source.
* 7. Test and run
-
Full check:
-
Gas pressure
-
Power Voltage
-
Match Map Connection
-
No gas leaks or electrical leaks
-
-
Boot the system from the central controller or from indoor unit.
-
Monitor the current, noise, vibration, wind temperature after 10 – 15 minutes of operation.
✅ 8. Maintenance and recommendations
-
Regular maintenance every 3 – 6 months:
-
Clean the cooling system
-
Gas pressure check
-
Squeeze the electrical connectors
-
Check fan outdoor unit And the capacitor boots
-
-
Do not keep the machine running for more than 24 h/day It's high-throughput.