Outdoor unit VRV A Cold Dimension RXQ14BYM – Enhanced Performance, Energy Savings

Outdoor unit VRV A Cold One-Dimensional Model RXQ14BYM The best choice for commercial buildings, office buildings, and high-end hotels with strong, stable, and power-efficient cooling is the air conditioning brand, which uses refrigerant R410A eco-friendly And it's integrating a lot of cutting-edge technology.
Technical specifications Highlights of outdoor unit RXQ14BYM:
-
Cooling capacity: 136,000 Btu/h ~ 40.0 kW
-
Power input: 9.88 kW
-
Refrigerant uses: Gas R410A
-
Dimensions (Size x Width x Depth): 1,660 x 1,240 x 765 mm
-
Weight: 247 kg
-
Type of machine: A cold one (cooling only)
The superiority of outdoor unit VRV A RXQ14BYM
✅ High Cooling Performance
With cooling capacity up to 136,000 Btu/h, RXQ14BYM meets the need for large space cooling, maintaining a stable and comfortable temperature even on the hot, hot, and sunny summer days.
✅ Power saving
Power input only 9.88 kWThis is a major plus for businesses interested in a financially efficient solution air conditioning.
✅ Design is neat – easy to install
Despite the power, the product was designed to size optimization (1,660 x 1,240 x 765 mm), easily accommodated in the building's technical space. Weight 247 kg It is suitable for transportation and installation using specialized equipment.
✅ Use refrigerant R410A
Gas R410A does not destroy ozone, which improves cooling efficiency and environmental protection. It is the new gas standard widely used on current high-end air conditioning lines.
Practical Application RXQ14BYM
outdoor unit VRV A RXQ14BYM suitable for installation of:
-
System central air conditioning VRV for Office building, shopping mall
-
Luxury Hotels, Restaurants, Resorts
-
Hospitals, schools, factories need professional, stable cooling systems
Why choose RXQ14BYM for your work?
-
Brand Loyalty
-
High efficiency, electricity saving
-
Easy integration in VRV system
-
Simple maintenance, genuine parts
-
Prestige warranty – professional after - sales service
Conclusion RXQ14BYM
Outdoor unit VRV Cold one - dimensional RXQ14BYM The first of two products, the first-generation cooling system, is an ideal cooling solution that ensures both operational performance and operational cost savings. With impressive technical specifications and outstanding features, the product deserves to be the first choice in modern central air conditioning projects.
🔧 1. Preinstallation preparation requirements
1.1 Installation Location
-
Somewhere open, unencumbered to ensure good air circulation.
-
Not near heat, exhaust or flammable objects.
-
Do not place in areas with high humidity, direct rain or standing water.
-
The minimum distance should ensure:
-
In front of outdoor unit: ≥ 1.5m
-
Side - by - side: ≥ 0.5m
-
Rear view: ≥ 0.3m
-
Top: ≥ 1.0 m (if multiple superlattices are installed)
-
✅ Note: Outdoor unit RXQ14BYM Heavy 247kgThe concrete floor or other support should be sufficiently load-bearing and vibration-resistant.
2 Foundation and support structure
2.1 Concrete foundations or supports
-
Floor Thickness Recommendations: ≥ 150mm
-
Usage anti-shock rubber pad at 4 the base
-
If it's on a high floor, we'll calculate load and vibration so that it doesn't affect the texture
2.2. Fixed outdoor unit
-
Use an expansion bolt or chemical bolt to secure the device to your nail.
-
Do not tilt, tilt, or place the device directly on the floor without rubber cushions.
🧰 3. Connection of copper and gas pipes
3.1. Type of gas used: R410A
-
Need of tools specifically for R410A (ejector tubes, pressure gauge, vacuum cleaner, etc.)
3.2. Copper pipe connection
-
Compliance pipe diameter and maximum length according to system design VRV.
-
Do not bend, flatten, or bend the tubing beyond the recommended radius.
-
Vacuum thoroughly before loading gas to remove moisture, avoid snowing or damage compressor.
The length and permissible height difference:
(Refer to technical documentation of Daikin or the system vendor VRV specifically – possibly from 165 m total length, 50 m differences according to system configuration)
⚡ 4. Electrical Connection
4.1. Sources
-
Power supply: 3 pha 380-415V / 50Hz
-
Power cord: select cross section by capacity (reference standard table)
-
Yes private aptomat for each outdoor unit, with propagation lightning if in a lightning - prone area
4.2. Signal wire
-
Use double wire with jam-resistant cover (2×1.25mm or more)
-
Do not use the same power cord to avoid interference
💧 5. Suspension drainage system (if any)
-
Some outdoor unit can produce condensate during operation at high humidity. Install a catch tray and drain if necessary.
-
The drain should be slightly sloped to ensure that the water runs naturally.
* 6. Test and run
6.1. Pre-running checks
-
Make sure all bolts are securely fastened
-
Check for leaking gas with a soapy solution or gas detector
-
Check the wiring, the phase, no loose ends
-
Make sure there is no obstruction at outdoor unit
6.2. Test and calibration
-
Power on, check fan rotation outdoor unit
-
Gas pressure and current consumption check
-
Monitor the system for at least 30 minutes to ensure stable operation
* 7. Technical and safety notes
-
Only technicians with expertise VRV are allowed to install and operate
-
Do not alter the plumbing, electrical design or installation structure without permission
-
Periodic maintenance 3 – 6 monthly depending on the operating environment
If you need actual installation scheme (Images, CAD drawings or PDF systems engineering VRV), would you like me to assist in creating or sourcing a standard template from your firm?