Packaged DAIKIN

FVGR400PY1/ RZUR400PY1

Product code: FVGR400PY1/ RZUR400PY1

Contact

Technical specifications: FVGR400PY1/ RZUR400PY1

+ Indoor Unit FVGR400PY1:

  • Cooling capacity: 40KW ~ 136,000 BTU/H (Cooling)
  • Electrical power consumption: 17.02KW (Cooling)
  • The amount refrigerant used: 8.2kg (R410A)
  • Voltage: 3 pha, 380V, 50Hz
  • Airflow: 120 m³/min
  • Static pressure: 147 Pa
  • Noise: 61 dB
  • Machine size (HxWxD): 1,870 × 1,170 × 720 mm
  • Weight: 200kg

+ Outdoor Unit RZUR400PY1:

  • Voltage: 3 pha, 380V, 50Hz
  • Airflow: 257 m³/min
  • Noise: 60 dB
  • Copper pipe size: Φ 12.7/28.6 mm
  • Machine size (HxWxD): 1,657 × 1,240 × 765 mm
  • Weight: 260kg
  • Max piping length: 70m

Original page prices at the date of copying 10/11/2026. Contact to confirm the current quotes.

PRODUCT DETAILS

Description & technical specifications

FVGR400PY1/RZUR400PY1 The Cold Sore Machine Daikin Packing Function – The Corporate Coolant Solution

Airshines Daikin FVGR400PY1/RZUR400PY1 belong to the family of industrial air-conditioning products, specifically designed to meet the cooling needs of large spaces such as offices, workshops or industrial areas.

FVGR400PY1/ RZUR400PY1

Technical specifications FVGR400PY1/ RZUR400PY1:

Indoor Unit:

  • Cooling capacity: 40KW ~ 136,000 BTU/H (Cooling)
  • Power input: 17.02KW (Cooling)
  • The amount refrigerant R410A: 8.2kg
  • Voltage: 3Pha/380V/50Hz
  • Airflow: 120 m³/min
  • Static pressure: 147 Pa
  • Sound pressure level: 61 dB
  • Size (HxWxD): 1,870 x 1,170 x 720 mm
  • Weight: 200Kg

Outdoor Unit:

  • Voltage: 3Pha/380V/50Hz
  • Airflow: 257 m³/min
  • Sound pressure level: 60 dB
  • Copper pipe size: Φ 12.7/28.6 mm
  • Size (HxWxD): 1,657 x 1,240 x 765 mm
  • Weight: 260Kg
  • Max pipe length: 70m

Highlights feature FVGR400PY1/ RZUR400PY1:

  • Superior cooling performance: With cooling capacity up to 40KW, Daikin FVGR400PY1/RZUR400PY1 air-conditioning provides powerful and efficient cooling of large spaces.
  • Energy efficiency: This product line has power input power only 17.02KW, which saves the operating costs of the business.
  • Refrigerant eco-friendly: Using refrigerant R410A, this air conditioner ensures high cooling efficiency while remaining environmentally friendly.
  • Airflow Powerful: With airflow up to 257 m/min for outdoor units, FVGR400PY1/RZUR400PY1 It can be refrigerated quickly and evenly.
  • Low Noise: Designed to reduce noise, with a noise level of only 60 -61 dB, provides a quiet and pleasant working environment.

Air conditioners Daikin FVGR400PY1/RZUR400PY1 are ideal options for large businesses, workshops, and structures, ensuring optimal cooling efficiency at reasonable operating costs.

The Practical Application of Cold Machine Daikin FVGR400PY1/RZUR400PY1

Air conditioners Daikin FVGR400PY1/RZUR400PY1 are ideal solutions for industrial and commercial environments that require robust, stable, and energy-efficient refrigeration. Here are some practical applications of this family of air conditioners:

  1. Offices and Tall Buildings: Air-conditioning Daikin FVGR400PY1/RZUR400PY1 machines provide efficient refrigeration for large office spaces, high-rise buildings, or crowded work areas. With cooling power up to 40KW, the machines can cool a large area, maintain a stable temperature, and provide comfortable working space.
  2. Works and Industrial Park: Because of its powerful cooling power and uniform temperature tuning over large space, this air conditioner is an ideal choice for manufacturing facilities, industrial parks, or warehouses. Maintaining the right temperature will help ensure product quality, minimize the risk of high-temperature damage, and improve productivity.
  3. Trade Center and Supermarket: Large shopping malls and supermarkets need a system air conditioning capable of rapid and efficient cooling. FVGR400PY1/RZUR400PY1 is the optimal solution, which helps maintain comfortable temperatures for customers and employees, while saving energy and minimizing operating costs.
  4. Hotel and Recreation Area: Luxury hotels, resorts, or convention centers require systems air conditioning that are uniformly refrigerated, smoothly operated, and energy efficient. Air conditioning Daikin FVGR400PY1/RZUR400PY1 can provide comfort to customers during their stay without overcharging costs.
  5. Hospitals and Health Authorities: Air conditioning is also important in hospitals and healthcare facilities where the work environment should be maintained clean, cool, and noise-free. FVGR400PY1/RZUR400PY1 with low noise and cooling capacity robustness helps create a quiet and comfortable space for patients and healthcare workers.
  6. Data Center and Server Room: Data centers and server rooms require a constant temperature to ensure efficient equipment operation. Air-conditioned Daikin FVGR400PY1/RZUR400PY1 machines with strong and stable refrigeration are a suitable solution for maintaining ideal temperatures for high-tech equipment in data centers.

With superior features such as large cooling capacity, energy saving, and low noise, Daikin FVGR400PY1/RZUR400PY1 airconditioning becomes the premier choice for applications in a variety of fields.

Installation and Operation Guide to Cold-Freeze Machine Daikin FVGR400PY1/RZUR400PY1

The installation and operation of air-conditioning Daikin FVGR400PY1/RZUR400PY1 should be performed by experienced professionals to ensure efficiency and safety. The following is a detailed guide to the steps of installation and operation.

1. Cold Machine Installation Instructions Daikin FVGR400PY1/RZUR400PY1

A. Pre-installation preparation:

  • Device Check: Check all components of the air conditioner, including the indoor unit and outdoor unit, to make sure there are no damage.
  • Select Installation Location: Choose an appropriate installation location for both indoor and outdoor units.
    • Indoor unit: Must have a well-ventilated space, easy access and no obstruction of the air flow.
    • Outdoor units: Must be placed in a well-ventilated location, away from direct sunlight and sources of emission disturbance to ensure operational performance.
  • Electrical System Inspection: Ensure the electrical system is in accordance with 3 phase 380 V/50 Hz requirements.

B. Indoor Unit Installation:

  1. Installation of a bracket: Secure the bracket on the wall or ceiling in the chosen position.
  2. Place and immobilize units in the house: Place the unit inside the house on a stand and make sure it is firmly secured. Check the balance to avoid shaking during operation.
  3. Connecting pipes and wires:
    • Connect the copper pipe to the unit's cooling units in your home.
    • Make sure all connectors are tightened to prevent leaks refrigerant.
    • Connect the electrical wires between the indoor unit and the 3 phase power system.

C. Installation of the Outdoor Unit:

  1. Set outdoor unit: Make sure the outdoor unit is located in an open and accessible location for maintenance.
  2. Connecting pipes and wires:
    • Connect the copper pipe from the indoor unit to the outdoor unit, paying attention to the maximum length of the pipe (70 m).
    • Connect the electrical wires in accordance with the diagram and ensure electricity safety.
  3. Noise Check: Check the noise of an outdoor unit to ensure that it operates within acceptable levels (60 dB).

D. Inspection and initial operation :

  1. The leak test refrigerant: Use a pressure test tool to ensure that there is no refrigerant leak in the duct system.
  2. Load refrigerant: Load refrigerant R410A (8.2 kg) if necessary.
  3. Test run: Turn on the machine and check the cooling functions. Make sure that the machine is working stably and that no errors are present.

2. Cold Machine Operation Instructions Daikin FVGR400PY1/RZUR400PY1

A. On Cold Machine:

  • Start System: Turn on the power and start the air conditioner via the remote panel or central control system. Select Cool Mode.
  • Temperature Setting: Adjust the temperature as needed (Usually from 22°C – 24°C for a comfortable working environment).
  • Fan Mode: Select the proper fan mode to adjust airflow (120 m/min for indoor units).

B. Noise Control and static pressure:

  • Sound pressure level: Air conditioners operate at low noise levels (61 dB for indoor units), ensuring they do not disturb the environment.
  • Static pressure: Check the static pressure of the air conditioner (147 Pa) to ensure that airflow is optimal.

C. Energy Consumption Management:

  • Energy efficiency: Air conditioners Daikin FVGR400PY1/RZUR400PY1 have power input only 17.02KW, which saves power. Set the energy-saving setting when no overcooling is required.

D. Regular maintenance and inspection

  • Clean air filters: Make sure the filter is cleaned periodically to maintain refrigeration.
  • Check refrigerant: Check the refrigerant count and add more if necessary.
  • Periodic inspection and maintenance: Set a regular maintenance schedule every 6 month to check machine performance and ensure no problems occur.

3 Important Considerations When Operating:

  • Do not place any obstructions in front of the air conditioning unit, as this will reduce the cooling effect.
  • Make sure that the electrical connections and pipes are tight and secure.
  • Avoid using the air conditioner in an environment with too much moisture or dirt.

Proper installation and operation will help air conditioning Daikin FVGR400PY1/RZUR400PY1 function efficiently, extending its life and saving energy.