VRV Air Conditioning Joint Stock CompanyCEO@vrv.com.vn

Packaged DAIKIN

4FGN600HY1

Product code: 4 FGN 600 HY 1

Contact

Technical specifications: 4FGN600HY1/RCN150HY19x4

  • Capacity: 60.000BTU
  • Type of machine: 1-way cooling-only
  • Types of Ga used: R410A
  • Feature Inverter: None
  • Warranties: 2 years for the entire machine, 5 years for compressor
  • Manufacturer: Daikin
  • Origin: Malaysia

Original page prices at the date of copying 10/11/2026. Contact to confirm the current quotes.

PRODUCT DETAILS

Description & technical specifications

The Wind Pipes-Associated Cold Machine Daikin 1-way cooling-only 4 FGN 600 HY 1/RCN150HY19x4 – Ideal Solutions for Your Space

4FGN600HY1/RCN150HY19x4

Air-pipe-connected air-conditioning Daikin 4 FGN 600 HY 1/RCN150HY19x4 is the perfect choice for spaces requiring efficient and economical cooling. With a capacity up to 60.000 BTU, the product meets the cooling needs of large room areas, such as offices, workshops, or public areas.

Technical specifications: 4 FGN 600 HY 1/RCN150HY19x4

  • Capacity: 60.000BTU
  • Type of machine: 1-way cooling-only
  • Types of Ga used: R410A
  • Feature Inverter: None
  • Warranties: 2 years for the entire machine, 5 years for compressor
  • Manufacturer: Daikin
  • Origin: Malaysia

Outstanding Advantages: 4 FGN 600 HY 1/RCN150HY19x4

  • Power strong: Airconditioning Daikin 4 FGN 600 HY 1/RCN150HY19x4 with a 60.000 BTU power will help you effectively cool even in large spaces.
  • Long - term warranty: The product is given a warranty of 2 five for the entire machine and 5 five for compressor, providing absolute security to the user.
  • Cost savings: Despite the absence of the Inverter feature, the console still ensures stable refrigeration performance and energy savings.
  • Gas use R410A: This is an environmentally friendly gas that ensures high cooling efficiency without harming the ozone layer.

Reasons for choosing a Wind Pipes-Associated Cold Machine Daikin 4 FGN 600 HY 1/RCN150HY19x4:

Air conditioners Daikin 4 FGN 600 HY 1/RCN150HY19x4 are designed to meet the cooling needs of spaces requiring air conditioning systems that provide rapid and powerful cooling. With its prestigious Daikin brand and superior quality, this product is worth a reliable choice for every family, company, or business facility.

Opt for a wind tunnel-pumped air conditioner Daikin 4 FGN 600 HY 1/RCN150HY19x4 to enjoy a cool, comfortable space and save on power bills.

Practical Application of the Wind Pipes-Associated Cold Machine Daikin 4 FGN 600 HY 1/RCN150HY19x4

Practical Application of the Wind Pipes-Associated Cold Machine Daikin 4 FGN 600 HY 1/RCN150HY19x4

The wind-pipe-connected air conditioner Daikin 4 FGN 600 HY 1/RCN150HY19x4 is an ideal cooling solution for spaces requiring large cooling power and a synchronously operating air conditioning system. Here are the common practical applications of this product:

  1. Office of the Secretary: Air-tube-connected Daikin refrigerators can be installed in office buildings to provide cool and comfortable working space. With a capacity of 60.000 BTU, they can provide rapid and uniform cooling, which can increase productivity for employees.
  2. Factories and Production Areas: In workshops or production areas where temperatures can be high due to constant machinery operation, maintaining a cool working environment is important. Air-tube-connected air-conditioning Daikin 4 FGN 600 HY 1/RCN150HY19x4 will help to control temperature effectively, protect worker health, and enhance production efficiency.
  3. Trade and Mall: With its fast cooling capability and wide cooling area, air-pumped air conditioning Daikin is an excellent option for shopping centers, supermarkets, or product display areas. This solution air conditioning not only provides comfort to customers but also maintains a comfortable shopping environment.
  4. Hotel and Recreation Area: Large-area hotels, resorts, or resorts can also benefit from air-conditioner ducting Daikin. The use of a ducting system will help distribute cold air uniformly throughout the entire area, providing a comfortable resort experience for visitors.
  5. Health Services and Hospitals: Air-pipe-connected Daikin air-conditioners are also useful in hospitals and healthcare facilities. A cool, comfortable environment is essential for patients and healthcare staff. Their efficient cooling system ensures that the air in patient rooms, treatment areas and corridors stays pleasant.
  6. Restaurants and cafes: Air-conditioner (A) fittings help air conditioning in restaurants and cafes, providing comfortable dining spaces for customers. The product can provide uniform refrigeration and avoid the presence of areas that are too cold or too hot, providing comfort to diners.

Detailed Instructions for Installation and Operation of Air-Tube Connecting Units Daikin 4 FGN 600 HY 1/RCN150HY19x4

Proper installation and operation of a windmill-pipe-connected Daikin air conditioner will help ensure optimal cooling performance and extend its life. Here are detailed instructions:

I. Instructions for Installation of Air-Generator-Air-Hybrid Daikin 4 FGN 600 HY 1/RCN150HY19x4

1. Installation Site Preparation:

  • Select Mount Location indoor unit (covered) so that air ducts are easily installed and ensure an even distribution of cold air throughout the room or area to be cooled.
  • Select Location outdoor unit (outdoor) outdoor or open space with no obstructions. Make sure there is enough space to escape heat and avoid noise.
  • Make sure that the installation site has a stable power source and the correct amount of power (220 V).

2. Installation indoor unit (4 FGN 600 HY 1):

  • Place indoor unit in the prepared position.
  • Install wind pipes that connect the indoor unit to the rooms or areas to be cooled. The wind pipes should be airtight and gapless to avoid air loss.
  • Insert the indoor unit bracket and make sure it is firmly attached, free of vibration during operation.

3. Installation outdoor unit (RCN150HY19x4):

  • Place the outdoor unit outdoors, away from obstructions or potential damage.
  • Install the gas co-conductor and the connecting pipes between outdoor unit and indoor unit. Make sure the connecting pipes are well protected and free of impact.
  • Connect the wires between indoor unit and outdoor unit, and check the electrical connections for safety.

4 Gas Feed and Seeping Test:

  • Use dedicated equipment to fill the system with R410A gas. Ensure that the gas is filled to the manufacturer's specifications.
  • Check all the joints, gas pipes, and connection points to make sure there are no gas leaks.

5. Electrical System Testing:

  • Check and confirm that all electrical connections and cables are secure and compatible with your computer's system.
  • Connect the computer to its main power source and turn on the power system.

II. OPERATIONAL GUIDANCE OF CONTAINERS OF WINDRAPHINE HYLINES Daikin 4 FGN 600 HY 1/RCN150HY19x4

1. Cold - Mode Installation:

  • Turn on the air conditioner and select the cooling mode on your console or remote.
  • Select the correct temperature for the space to be cooled. For this machine you can adjust the temperature from 16°C to 30°C depending on your needs.

2. Airflow Regulation:

  • You can adjust the speed of your fans and the direction of the wind to suit the space you're cooling.

3. Checks and Controls Settings:

  • Check the cooling efficiency of the system, if necessary, adjust the temperature or fan speed to achieve optimal performance.
  • Make sure that indoor unit and outdoor unit are not overloaded or in distress.

4. Maintenance and Periodic Hygiene:

  • Clean the air filters once a month to ensure fresh air and increase the cooling effect.
  • Periodically inspect wind pipes, gas pipes and electrical systems to detect problems in a timely manner.

III. Important Considerations When Using:

  • Avoid starting your engine when there are electrical issues Like a power outage or voltage malfunction.
  • Make sure there's no obstruction around indoor unit and outdoor unit to avoid degradation of cooling performance and malfunction.
  • Do not change internal settings arbitrarily This will prevent any damage to the machine if no technicians are available.

IV. Common Errors and Remedial Methods

  1. Cold machine: Check the gas level, see if the pipes are leaking. If there is a shortage of gas, refill as required.
  2. The loud noise generator: Check the connections and screw nuts of indoor unit and outdoor unit to ensure they are firmly attached and not loose.
  3. Machine does not work: Check the power supply and the wiring.

Conclusion:

The installation and operation of a windmill-coupled air conditioner Daikin 4 FGN 600 HY 1/RCN150HY19x4 should be performed carefully and in a proper manner to ensure optimal cooling efficiency and to extend the life of the product. If any problems arise, contact the team of technicians for assistance.