Daikin FVGR250PV1/RZUR250PY1 Packaging – cooling capacity 91,000 BTU/H

The Daikin FVGR250PV1/RZUR250PY1 package offers an efficient cooling solution for large spaces with the following notable features:
Technical specifications FVGR250PV1 / RZUR250PY1:
Indoor Unit FVGR250PV1:
- Cooling capacity: 26.7KW (91,000 BTU/H) – Ensure rapid and robust cooling.
- Electrical power consumption: 9.64KW (Cooling) – Optimal energy saving.
- The amount refrigerant R410A: 6.7kg – refrigerant environmentally friendly, high cooling performance.
- Voltage: 1 Pha / 220 V / 50 Hz – This is easily connected to your home power source.
- Airflow: 80 m3/min – Distribute air evenly throughout space.
- Noise: 61 dB – Quiet, no harsh noises.
- Machine size (HxWxD): 1,870 x 1170 x 510 mm – Strong design, good for multiple spaces.
- Weight: 149Kg – Ensure durability and stability throughout use.
Outdoor Unit RZUR250PY1:
- Voltage: 3 Pha/380 V/50 Hz – Consistent with industrial 3 phase-mode electrical systems.
- Airflow: 178 m3/min – Efficient cooling, air circulation.
- Noise: 57 dB – Quiet, low - noise, unpleasant.
- Copper pipe size: Φ 9.5/22.2 mm – Strong connection, easy to set up.
- Machine size (HxWxD): 1,657 x 930 x 765 mm – Clean design, easy to set up outside.
- Weight: 185Kg – Robust and stable, suitable for large projects.
- Max piping length: 70 m – Easy to install at long distances, flexible in large structures.
Outstanding Advantages FVGR250PV1 / RZUR250PY1:
- High cooling efficiency with a capacity up to 91,000 BTU/H, suitable for large area areas.
- Energy efficiency And that's because power input electricity is rational, which reduces operating costs.
- Smooth OperationIt's low noise, it doesn't affect the surrounding space.
- Compact designIt is easy to install and maintain.
- Refrigerant R410A eco-friendly, safe for the health of users.
Daikin FVGR250PV1/RZUR250PY1 gallons are ideal options for buildings that require robust, efficient and energy efficient air conditioning systems.
Practical Application of Cold Machine Daikin FVGR250PV1/RZUR250PY1 Packaging
Air-conditioned Daikin FVGR250PV1/RZUR250PY1 packages with robust cooling capacity and energy-consuming efficiency, are ideal for many practical applications, especially those with large spaces or requiring continuous air conditioning. Here are some common applications:
1. Business and office buildings
- Applications: Air conditioners Daikin can provide uniform cooling to office buildings or trade centres, helping to maintain a comfortable working environment for staff and customers.
- Benefits: Low - power, smooth - motion, and easy maintenance.
2 Industrial parks and manufacturing plants
- Applications: This refrigerator is suitable for manufacturing plants, processing plants, or cold storage, where steady temperatures need to be maintained to protect products or ensure the performance of machines.
- Benefits: Strong cooling capability helps increase productivity, protecting the device from high temperatures.
3. Server rooms and data centers
- Applications: This air conditioning, with its fast and stable cooling, is an excellent solution for server rooms, data centers where electronic equipment works constantly and generates heat.
- Benefits: Make sure the temperature stays at an ideal level, and protect your electronics and server system from overheating.
4. Hospitals and health facilities
- Applications: This air conditioner can be used in clinic areas, hospitals, or medical centers, which require cool and clean spaces to support treatment and health care.
- Benefits: Effective cooling in medical environments, which minimizes the risk of high temperature - induced illnesses.
5. Resort, hotel and tourist attractions
- Applications: Air conditioners Daikin suitable for resorts, hotels, or tourist resorts with large spaces, require robust and stable air conditioning systems to meet customer needs.
- Benefits: Make sure the room is comfortable even on hot summer days.
6. Educational institutions (schools, universities)
- Applications: Schools, especially universities with classrooms, halls, or public areas, may apply air conditioning Daikin to maintain a comfortable learning environment.
- Benefits: Keeping the air cool will help students and faculty focus better during class.
Daikin FVGR250PV1/RZUR250PY1 Containers offer not only superior refrigeration performance but also ease of installation and operation in a variety of environmental conditions.
Installation and Operation Guide for Cold Machines Daikin FVGR250PV1/RZUR250PY1
Air-conditioning Daikin FVGR250PV1/RZUR250PY1 installations and operations require thorough preparation and proper process execution to ensure optimal performance. Here is detailed guidance from installation through to operation:
1. Preinstallation preparation
The Tools and Materials That Are Required:
- Pliers, screwdrivers, wrenches, hammers
- Solders and copper pipe cutters
- Copper pipes ( Φ 9.5/22.2 mm) and accessories (joints, valves, etc.)
- Voltage tester, pressure gauge refrigerant
- Welding instruments, insulation
- Make sure the space is large enough and well ventilated
2. Indoor Unit Installation
Step 1: Locate the installation
- Choose a spot in your home that will distribute air evenly throughout the space.
- Avoid obstructions like furniture and windows to allow for the best air circulation.
- Make sure the space is large enough for the machine size 1,870 x 1,170 x 510 mm.
- Set up at an altitude at least 2,5 m above the floor to ensure optimal cooling.
Step 2: Installation of the Indoor Unit
- Attach the bracket to the wall or ceiling to make sure it is sturdy enough to support the weight of the air conditioner 149Kg.
- Make sure the rack is placed at a balanced angle (about 3 -5 degrees) to ensure drainage from the air conditioner.
Step 3: Copper Tube Connection and refrigerant
- Take the copper pipe from the Outdoor Unit into the Indoor Unit through the prepared position.
- Welding the connectors of copper tubing firmly together and using insulating material prevents leakage or loss of cold.
Step 4: Power Connection
- Power connection 1Pha/220V/50Hz Into the device according to the manufacturer's circuit diagram.
- Check all electrical connections carefully for safety before using them.
3 Outdoor Equipment
Step 1: Locate the installation
- Choose an outdoor location that is well ventilated, away from direct sunlight, dirt, or other obstructions.
- Make sure there is minimal space for maintenance and removal of equipment as needed.
- Machine size 1,657 x 930 x 765 mm, weight 185KgChoose a sturdy, sturdy foundation.
Step 2: Copper Tube Connection and refrigerant
- Run the copper pipes from the Indoor Unit to the Outdoor Unit. Welding firmly and testing the leakage of the system using nitrogen gas or leakage testing equipment.
- Ensuring the copper pipes are not overbending and free of obstructions, helps to optimize the flow of refrigerant.
Step 3: Power Connection
- Power connection 3Pha/380V/50Hz with the Outdoor Unit according to circuit diagram.
- Check the electrical connections to ensure safety and standard before operating.
Step 4: Test the Piping System
- Measure and ensure the total tube length does not exceed 70m, ensures efficient refrigeration and no overcrowding or loss refrigerant.
4 Cold Machine Operation
Step 1: System Testing
- Check all electrical connections, copper pipes, and refrigerant to make sure there are no leaks.
- Make sure the valves are open and the equipment is connected properly.
Step 2: Load refrigerant R410A
- If the machine is not preloaded refrigerant, load 6.7kg Refrigerant R410A Check the pressure and charging level to be consistent with the manufacturer's specifications.
Step 3: Enable Machine and Check
- Turn on the Machine and adjust the temperature as required. The Machine will automatically cool the space.
- Check the airflow and noise levels:
- Indoor Unit: Airflow 80 m3/min, Noise 61 dB.
- Outdoor Unit: Airflow 178 m3/min, Noise 57 dB.
Step 4: Regulate and operate
- Set your cooling system and check that it is running smoothly and efficiently.
5. Maintenance and Maintenance
- Clean the filter: Check and clean the air filters periodically to maintain cooling efficiency.
- System checks refrigerant: Check the pressure refrigerant at least once every month 6.
- Sanitizing outdoor unit and indoor unit: Outdoor unit and indoor unit should be cleaned annually to ensure cooling efficiency.
- Electrical system checks: Make sure that your electrical connections are maintained and there are no signs of damage or leakage.
Important Considerations
- Do not install air conditioning in areas with high humidity, easy to flood, or direct sunlight.
- Make sure all installed equipment is in accordance with manufacturer instructions and national safety standards.
- The installation and maintenance of air conditioners must be performed by professional technicians to avoid any incidents during the operation.
Hopefully, this detailed guide will help you to install and operate air conditioning Daikin FVGR250PV1/RZUR250PY1 packages easily and efficiently.