Technical specifications Highlights: FDR500PY1/RZUR500PY1

Indoor Unit:

  • Cooling capacity: 50KW ~ 171,000 BTU/H (Cooling)
  • Electrical power consumption: 26.74KW (Cooling)
  • The amount refrigerant R410A: 11.7kg
  • Voltage: 3 pha/380V/50Hz
  • Airflow: 166 m³/min
  • Noise: 60 dB
  • Machine size (HxWxD): 625 x 1,980 x 850 mm
  • Weight: 191 kg

Outdoor Unit:

  • Voltage: 3 pha/380V/50Hz
  • Airflow: 297 m³/min
  • Noise: 65 dB
  • Copper pipe size: Φ 15.9/28.6 mm
  • Machine size (HxWxD): 1,657 x 1,240 x 765 mm
  • Weight: 291 kg
  • Max piping length: 70m

Original page prices at the date of copying 10/11/2026. Contact to confirm the current quotes.

PRODUCT DETAILS

Description & technical specifications

FDR500PY1/RZUR500PY1 The Factory for Cold Defficiency Daikin Packaged: Strong Cold Performance, Save Lives

The Daikin Compensated FDR500PY1/RZUR500PY1 air-conditioning machine is an ideal choice for buildings that require large cooling capacity and stable operational performance. With its solid design and superior features, this product meets the cooling needs of large spaces, such as office buildings, workshops, and public areas.

FDR500PY1/RZUR500PY1

Technical specifications Highlights: FDR500PY1/RZUR500PY1

Indoor Unit:

  • Cooling capacity: 50KW ~ 171,000 BTU/H (Cooling)
  • Electrical power consumption: 26.74KW (Cooling)
  • The amount refrigerant R410A: 11.7kg
  • Voltage: 3 pha/380V/50Hz
  • Airflow: 166 m³/min
  • Noise: 60 dB
  • Machine size (HxWxD): 625 x 1,980 x 850 mm
  • Weight: 191 kg

Outdoor Unit:

  • Voltage: 3 pha/380V/50Hz
  • Airflow: 297 m³/min
  • Noise: 65 dB
  • Copper pipe size: Φ 15.9/28.6 mm
  • Machine size (HxWxD): 1,657 x 1,240 x 765 mm
  • Weight: 291 kg
  • Max piping length: 70m

Notable advantages of Cold Machines Daikin FDR500PY1/RZUR500PY1:

  • High Cooling Performance with a power up to 171,000 BTU/H, suitable for large-area spaces.
  • Power saving with consumption only 26.74KWIt's a cost-effective way to reduce operating costs.
  • Design Persistence lightweight and neat in size, easy to install and maintain.
  • Low Noise It ensures a quiet environment in which to use.
  • Easy to install and operate with pipe lengths up to 70 m, suitable for complex structures.

Air conditioning Daikin FDR500PY1/RZUR500PY1 is the perfect solution for buildings that need efficient, sustainable, and energy-efficient cooling systems.

Practical Application of Cold-Factors Daikin FDR500PY1/RZUR500PY1

FDR500PY1/RZUR500PY1

Daikin FDR500PY1/RZUR500PY1 gels with robust cooling power and stable operational performance can be widely used in a variety of fields. Here are some examples of practical applications:

1. Office Buildings

  • Meeting refrigeration needs for office buildings: With capacity 50KW, air conditioning Daikin FDR500PY1/RZUR500PY1 helps maintain a comfortable work environment for large numbers of employees, especially in offices, multilevel buildings, or open work areas.

2. Factories and Product Areas

  • Refrigeration for production space and storage: Air conditioners Daikin can maintain stable temperatures in workshops, which protects product quality, minimizes errors during production, and enhances labor productivity.

3. Trade Centers and SuperMarkets

  • Keep the space cool and comfortable for customers: In large shopping centers or supermarkets, powerful refrigeration systems help create comfortable spaces for shoppers, thereby enhancing the shopping experience.

4. Public areas and Conference Center

  • Ensure ideal temperatures for events and conferences: The cooling system Daikin FDR500PY1/RZUR500PY1 is designed for rapid and efficient cooling, suitable for public areas such as convention centers, gymnasiums, or exhibition fairgrounds.

5. The Highrise Apartments

  • Cooling solutions for apartment buildings: With efficient refrigeration and low power consumption, this air conditioner is ideal for high-rise apartment buildings, ensuring an ideal living environment for residents.

6. Big Construction Projects

  • System air conditioning for large - scale projects: Air-conditioning Daikin FDR500PY1/RZUR500PY1 can be used in large construction projects, where the air conditioning system requires robustness, which can cool large areas and maintain a steady temperature during construction.

Thanks to its high-efficiency, energy-efficient features and durable operation, Daikin FDR500PY1/RZUR500PY1 capsulated air-conditioning is an ideal cooling solution for buildings requiring large cooling capacity and high efficiency.

Detailed Instructions for Machine Installation and Operation air conditioning Industry Daikin Packaging FDR500PY1/RZUR500PY1

Detailed Instructions for Machine Installation and Operation air conditioning Industry Daikin Packaging FDR500PY1/RZUR500PY1

The installation and operation of industrial air conditioning Daikin FDR500PY1/RZUR500PY1 machines requires precision to ensure optimal performance and long life of the equipment. Here is detailed guidance:

1. Preinstallation preparation

Device Testing

  • Make sure all of the components are in place and that they are not damaged during shipping.
  • Check the technical specifications such as voltage, type refrigerant (R410A), pipe length, and size of the parts.

Select Installation Location

  • Indoor Unit: Choose a location in your home that is unobtrusive and accessible for maintenance and cleaning.
  • Outdoor Unit: Choose a well-ventilated, unobstructed location that is away from direct sunlight or weak air flow. Make sure the distance is long enough to avoid obstruction airflow.

2 In - Home Unit Installation

  • Step 1: Attach a sturdy bracket to the wall or ceiling, making sure the machine does not shake during operation.
  • Step 2: Install ducts to the inside of your unit's doors and exits.
  • Step 3: Connect the refrigerant(R410A) ducts from an outdoor unit to an indoor unit. Be careful to ensure that the ducts do not bend or bend, and to keep a minimum of distance between the ducts.
  • Step 4: Double check the electrical connections in your home, making sure they are properly charged and securely connected.

3 Installation of the Outdoor Unit

  • Step 1: Secure brackets or platforms for outdoor units. Ensure outdoor units are unhindered airflow.
  • Step 2: Connect the copper pipes from the indoor unit to the outdoor unit. Make sure the copper pipes are connected firmly and do not leak.
  • Step 3: Connect the power supply to the outdoor unit. Check these connections for safety.

4. Electrical System Integration

  • Step 1: Double check your entire electrical system, including circuit breakers, protective equipment, and electrical connections between components.
  • Step 2: Make sure to use the right protective fuses and cables for your computer.
  • Step 3: Connect your computer to a 3 phase/380 V/50 Hz power supply.

5 Pre-operation Inspection and Maintenance

  • Testing refrigerant: Make sure there is enough refrigerant (R410A) and the right type. Check for refrigerant leaks at the connection points.
  • Pipeline Testing: Make sure the pipes don't leak and flow naturally.
  • Electrical Check: Check all electrical connections and switches to ensure that the system is functioning properly.

6. Operation of the Machine air conditioning Daikin FDR500PY1/RZUR500PY1

Start Machine

  • Step 1: Turn on the power and check your connections.
  • Step 2: Enable air conditioning and select the cooling mode on the remote.
  • Step 3: Make sure the machine is running smoothly, with no strange noises or shudders , Check the room temperature after the machine starts to run

Adjustment and Settings

  • Freeze Mode: Make sure to choose a cooling setting that is appropriate for the temperature of the space.
  • Airflow: Adjust airflow to fit the space used and the user's requirements.
  • Moisture: For areas that need humidity control, you can combine the air conditioning machine with dehumidifiers if necessary.

7. Periodic Maintenance and Sanitation

  • Clean Air Filters: Clean your computer's filters periodically to maintain the best cooling performance and reduce noise.
  • Testing refrigerant: Check and add refrigerant if necessary, avoiding the lack of refrigerant that affects refrigeration performance.
  • Outdoor Unit Sanitation: Clean the propeller and outdoor unit unit outdoors, avoiding dust that reduces cooling performance.

Important Considerations

  • Avoid over-loading or wind - blocked conditions.
  • If you notice any signs of an issue, stop the machine and contact a warranty service or experienced technician to check and fix it.

By following these installation and operation steps, the industrial air conditioning Daikin FDR500PY1/RZUR500PY1 machine will operate efficiently, save energy, and ensure a long life.