Outdoor unit VRV LG water-cooled ARWM120LAS5 – Efficiency and Convenience
Outdoor unit VRV LG water-cooled ARWM120LAS5 is ideal for large projects, offering superior cooling and heating capabilities with high efficiency. Here, we provide a detailed description of this product.

1. technical specifications prominent outdoor unit VRV LG ARWM120LAS5
- Cooling capacity: 33.6KW
- Heating capacity warm: 37.8KW
- Index COP: 6.8 W/W, ensuring optimal energy efficiency.
- Power supply: 3 Phase/380 V/50 Hz, suitable for industrial and commercial systems.
- Cold-direction power: 5.14KW
- Warm up current power: 5.56KW
2. Design and operation characteristics
- Compact size: 772 x 1,120 x 547 mm, easily installed in confined spaces.
- Weight: 149kg(NET) and 157kg(SHIPPING), convenient for delivery.
- Low Noise: 60 dB(A) (cooling) and 63 dB(A" (warming), suitable for environments that require quiescence.
- Refrigerant: R410a – environmentally friendly and high performance guaranteed.
3. Superior heat exchange efficiency
- Heat exchange water flow: 115 LPM, which optimizes cooling efficiency.
- Connection pipe: Size 40 A, ensuring efficient transmission.
- Pipes refrigerant: D12.7/D28.58, compatible with a wide variety of systems.
4. Maximum connectivity and flexible applications
- Number of compressors: 1 which ensures stable and durable operation.
- Number indoor unit max connections: 20 (up to 30), suitable for office buildings, hotels, and shopping malls.
5. The outstanding advantages of outdoor unit VRV LG ARWM120LAS5
- High performance with advanced technology: The COP 6.8 W/W index offers significant energy savings.
- Persistent Activity: refrigerant R410a combined with modern heat exchange systems yields high longevity.
- Environment-friendly: Low noise, user-friendly.
Why choose outdoor unit VRV LG ARWM120LAS5?
- The product delivers superior performance, meeting the needs of large constructions.
- Modern design, easy to install and maintain.
- Manufactured by LG - the leading refrigeration brand.
Please contact us immediately for the best advice and advice for outdoor unit VRV LG ARWM120LAS5!
Practical Application of outdoor unit VRV LG ARWM120LAS5
Outdoor unit VRV LG ARWM120LAS5 is designed to meet the cooling and heating needs in large constructions. With high performance and versatility, this product is suitable for a wide range of environments and practical applications such as:
1 The office building
- Ensure a comfortable working environment year round thanks to the ability to maintain a steady temperature air conditioning.
- Integration of maximum connectivity up to 20 – 30 indoor unit, serving multiple floors and departments.
- Energy efficiency with a high index of COP, reducing operating costs for businesses.
2. The Trade Center
- High power provides effective cooling or heating in large spaces.
- Low noise, providing a comfortable experience for customers when shopping.
- Compact design, easy to install in the technical areas of the center.
3 Hotels and Resorts
- Support air conditioning for multiple living rooms and public areas at once.
- Meet high standards for quiet environment and comfortable spaces for guests.
- Being green will help your business's "green" image.
4. Hospitals and Health Facilities
- Maintaining the right temperature will ensure the health and safety of your patient.
- High performance with refrigerant R410a, safe and environmentally benign.
- Robust systems, minimizing the risk of interruptions in busy health facilities.
5 Factories and Industrial Parks
- Conform to cooling systems in production lines or warehouses containing temperature-sensitive goods.
- Easy integration with existing air conditioning systems, increased cooling efficiency.
6 Schools and training institutions
- Make sure the temperature is optimal for classes, meeting rooms, and shared areas.
- Reduce long - term operating costs due to high energy efficiency.
With its diverse applications and outstanding performance, outdoor unit VRV LG ARWM120LAS5 is ideal for projects that require comfort, energy savings, and reliability. Consider this product to enhance the value and efficiency of your work!
Installation Details Manual outdoor unit VRV LG ARWM120LAS5
The proper installation of outdoor unit VRV LG ARWM120LAS5 not only ensures performance but also increases product lifetime. Here is detailed installation procedures:
1. Preinstallation preparation
- Product Testing: Ensure the products are intact and not damaged during the transportation.
- Select Installation Location:
- Make sure there is enough room for the installation (according to machine size: 772 x 1,120 x 547 mm).
- A well - ventilated area, away from direct sunlight and high humidity.
- Make sure the substrate is flat and firm to avoid shaking during operation.
- Tools required: Hand-held tool kits, solders, copper pipes, water pipes, insulation, and pressure gauges.
2 Installation of the Interconnection System
a. Pipeline connection refrigerant
- Use suitable sized copper tubing: D12.7/D28.58.
- Protect the tubing with a heat protectant layer to prevent heat loss and stagnation.
- Make sure the connections are sealed to prevent leaks.
b/Connecting water pipelines
- Select a size pipe 40A in accordance with technical requirements.
- Connected to the heat exchange system, guaranteed water flow at 115 LPM.
c/Connection of power systems
- Use 3 phase, 380 V, 50 Hz power.
- Make sure the wires are rated for load bearing.
- Connect the poles correctly (Part, Medium, Earth) according to manufacturer instructions.
3 Machine Installation and Fixation
- Place the machine on a sturdy support, making sure it doesn't tilt or shake.
- Use a fixed bolt to minimize noise and vibration when the machine is running.
4 Testing and Refinement
a. Pressure and leakage inspection
- Use a pressure gauge to test the refrigerant pipeline system.
- Make sure there are no leaks at the junctions.
b. Water flow checking
- Ensure that the water pipeline system is running smoothly and that the flow rate is at 115 LPM.
c. Test run
- Power on and check the outdoor unit activity.
- Noise measurements (60 dB(A) for cooling and 63 dB(A )for heating) to ensure that the machine is operating in the proper standard.
5. Installation Notes
- Electrical safety: Power cut before installation or maintenance.
- Installation Distance: Maintain a minimum distance between outdoor unit and surrounding objects to ensure a clear air flow.
- Periodic maintenance: Clean outdoor unit and check the system at least 6 monthly.
Accurate installation will optimize the performance of outdoor unit VRV LG ARWM120LAS5. If you are having difficulty, contact a professional technical team for assistance!