VRV Air Conditioning Joint Stock CompanyCEO@vrv.com.vn

Packaged DAIKIN

3FGN350HY1/RCN125HY19x2

Product code: 3 FGN 350 HY 1/RCN125HY19x2

Contact

Product details: 3FGN350HY1/RCN125HY19x2

  • Model: Daikin 3FGN350HY1/RCN125HY19x2
  • Capacity: 35.000 BTU
  • Type of machine: 1-way cooling-only (cooling only)
  • Feature Inverter: None
  • Gas type used: R410A, eco-friendly and energy - efficient
  • Origin: Malaysia
  • Warranties: 2 years for the entire machine, 5 years for compressor

Original page prices at the date of copying 10/11/2026. Contact to confirm the current quotes.

PRODUCT DETAILS

Description & technical specifications

The Wind Pipes-Associated Cold Machine Daikin 1-way cooling-only 3 FGN 350 HY 1/RCN125HY19x2 – Ideal Solutions for Your Space

3FGN350HY1/RCN125HY19x2

Air-pipe-connected air-conditioning Daikin 1-way cooling-only 3 FGN 350 HY 1/RCN125HY19x2 is the perfect choice for large spaces such as offices, workshops, or commercial areas. Possessing a state-of-the-art design and high cooling performance, the product offers cool and comfortable spaces for its users.

Technical specifications: 3 FGN 350 HY 1/RCN125HY19x2

  • Capacity: 35.000 BTU – Meet the need for efficient refrigeration for large - area spaces.
  • Type of machine: 1-way cooling-only – Refrigerated only, suitable for areas that do not require heating.
  • Feature Inverter: No – Fits simple, cost - effective needs.
  • Type of gas used: R410A – Advanced, eco-friendly refrigeration technology.
  • Origin: Malaysia – Ensure high quality and outstanding durability.
  • Manufacturer: Daikin – Global brand name for products air conditioning.

Warranty: 3 FGN 350 HY 1/RCN125HY19x2

  • 2 year complete, 5 years to compressor – Commitment to quality and long - term support for customers.

With its robust capacity and outstanding durability, the windmill-pumped air-conditioner Daikin 1-way cooling-only 3 FGN 350 HY 1/RCN125HY19x2 is ideal for spaces that require high cooling efficiency and stability.

Practical Application of Air-Tube Coupler Cold Machine Daikin 1-way cooling-only 3 FGN 350 HY 1/RCN125HY19x2

3 FGN 350 HY 1/RCN125HY19x2-practical application

The wind-pipe-powered air-conditioner Daikin 1-way cooling-only 3 FGN 350 HY 1/RCN125HY19x2 is designed to serve large spaces and requires high cooling performance. Here are some practical applications of this product:

  1. Business Office: Air-pipe-connected air-conditioning Daikin 3 FGN 350 HY 1/RCN125HY19x2 is suitable for large-area offices, which helps to create a cool and comfortable working environment for employees. The air-pipe system helps to distribute cold air evenly throughout the space.
  2. - Buildings, workshops, warehouses and storing yards: With high-volume 35.000 BTUs, this air conditioner can effectively cool production or storage areas, which are large in size and require stable temperature conditions to preserve goods or maintain a good working environment for workers.
  3. Trade Center, Super Market: Commercial areas, such as shopping centres or supermarkets, need air conditioning that is robust and energy efficient. Daikin 3 FGN 350 HY 1/RCN125HY19x2 with gas utilization R410A helps maintain ideal temperatures for customers and shoppers.
  4. Hotel, Restaurant: This air conditioner is a perfect choice for large hotel or restaurant spaces, keeping air conditioning cool during the entire serving period. With its powerful cooling power and smooth operation, customers will feel more comfortable.
  5. The Tall Building: In high-rise buildings, using a duct-taped air-conditioning system such as Daikin helps to cool multiple rooms simultaneously without the need to install too many individual air-conditioning units, saving space and maintenance costs.

With these practical applications, the windguide-connected air conditioner Daikin 1-way cooling-only 3 FGN 350 HY 1/RCN125HY19x2 is an efficient and economical solution for spaces requiring large and stable cooling power.

Installation and Operation Guide for Wind Tape Connecting Cold Machine Daikin 1-way cooling-only 3 FGN 350 HY 1/RCN125HY19x2

1. Preinstallation preparation 3 FGN 350 HY 1/RCN125HY19x2

Before you install it, you need the following:

  • Examine machine parts: Make sure you have received all of your air conditioning components including indoor unit, outdoor unit, remote, parts kit, and air hose.
  • Select Installation Location:
    • indoor unit: This should be installed in a well-ventilated area with no major obstructions. This should be at least 30 cm away from the ceiling to ensure an even distribution of the airflow.
    • outdoor unit: It should be installed in a well-ventilated area, away from direct sunlight and obstacles. The minimum distance from outdoor unit to the obstacles is 1 m.
    • Wind pipe: Make sure the connectors are firmly installed and not bent too much so as not to affect cooling performance.

2. Installation of the Wind Pipes-Associated Coldglow 3 FGN 350 HY 1/RCN125HY19x2

Step 1: Assemble indoor unit

  1. Mark the position of indoor unit hanging on the wall, ensuring that indoor unit is hanging at a reasonable height and is easily connected to the wind tunnel.
  2. Attach the bracket to the marked spot on the wall, making sure it is secure.
  3. Hang indoor unit on a mount and check the stability of the device.

Step 2: Assemble outdoor unit

  1. Choose an outdoor installation location outdoor unit, making sure that the space is open and free of obstacles.
  2. Place outdoor unit on a sturdy stand or substrate. Make sure outdoor unit is installed with a slight back tilt to avoid condensation water being trapped in outdoor unit.
  3. Connect the gas pipe from indoor unit to outdoor unit. Make sure the pipe does not bend too hard or bend.

Step 3: Wind Connecting

  1. Attach the air ducts from indoor unit to the doors in your room, making sure they are not bent or obstructing airflow.
  2. Check the connections between the wind tunnel and the outlets to make sure there are no leaks.

Step 4: Electrical Connection

  1. Connect the power cord to the air conditioner. Make sure to use a wire with appropriate and safe cross-section.
  2. Check the power system before starting to ensure there are no electrical issues.

3. Postinstallation checks 3 FGN 350 HY 1/RCN125HY19x2

Once the installation is complete, take the following steps:

  • Electrical System Inspection: Ensure safe electrical connections without signs of fire.
  • Gas system test: Make sure no gas leak occurs. If necessary, request the technician to check.
  • Check machine performance: Turn on the air conditioner and check the operation of indoor unit and outdoor unit, making sure there are no strange noises and the air conditioner is efficient.

4. Cold Machine Operation Guide 3 FGN 350 HY 1/RCN125HY19x2

  1. Turn on Machine: Use the remote to turn on the machine. Make sure that indoor unit works and that cold air is evenly blowing across the room.
  2. Adjust temperature and mode: You can adjust the temperature, fan speed, and other settings (e. g. , cooling, auto, fan) as needed.
  3. Use of additional features (if any):
    • Power saving mode: Air conditioners Daikin can have energy-efficient features, which reduce the power consumed during operation.
    • Dehumidifier Mode: If the air is damp, use a dehumidifier to reduce the humidity in the air.

5. Maintenance and Periodic Operation 3 FGN 350 HY 1/RCN125HY19x2

  • Clean the air filter: Periodically clean the air filter to ensure the best cooling performance and extend the life of the air conditioner.
  • Wind pipe test: Make sure the wind tunnel is not blocked and that the air flow is always clear.
  • Check for cold gasIf the air conditioner does not cool you effectively, you may need to fill it with more cold air. Have a technician check and treat your problem.

6. Important Considerations 3 FGN 350 HY 1/RCN125HY19x2

  • Avoid installing in direct sunlight or high temperaturesThis will reduce cooling efficiency and cause more energy loss.
  • Ensure periodic maintenance: Maintain and clean air conditioning at least 6 monthly to ensure good performance and extend its life.

Proper installation and operation will result in air conditioning Daikin 3 FGN 350 HY 1/RCN125HY19x2 operation stability and long-term energy savings.