Product code: 2 FGN 300 HY 1

Contact

Technical specifications: 2FGN300HY1

  • Model: 2FGN300HY1/RCN150HY19x2
  • Capacity: 30.000 BTU
  • Type of gas used: R410A
  • Origin: Malaysia
  • Feature Inverter: None
  • Warranty: 2 year complete machine, 5 year compressor

Original page prices at the date of copying 10/11/2026. Contact to confirm the current quotes.

PRODUCT DETAILS

Description & technical specifications

The Wind Pipes-Detached Cold Machine Daikin Daikin 1-way cooling-only 2 FGN 300 HY 1/RCN150HY19x2 – Your Space's Modern Coolant Solution

2FGN300HY1

Air-pipe-connected air-conditioning Daikin 2 FGN 300 HY 1/RCN150HY19x2 is an ideal choice for spaces requiring efficient and area-efficient cooling systems. With a concealed ceiling design, the product offers exquisite beauty, suitable for a wide range of structures such as offices, hotels, or residences.

Technical specifications: 2 FGN 300 HY 1

  • Model: 2FGN300HY1/RCN150HY19x2
  • Capacity: 30.000 BTU
  • Type of gas used: R410A
  • Origin: Malaysia
  • Feature Inverter: None
  • Warranty: 2 year complete machine, 5 year compressor

Product Superiority: 2 FGN 300 HY 1

  • High Capacity 30.000 BTU, suitable for large spaces such as offices, meeting rooms, or business areas.
  • Hide & Ceiling Design Subtle, not infringing on the interior space.
  • Use of gas R410A It's a fast, energy - efficient refrigeration.
  • Long-term Warranty: Warranty 2 year for the entire machine and 5 year for compressor, ensuring safety during use.

The air-conditioning Daikin 2 FGN 300 HY 1/RCN150HY19x2 is an optimal solution for those seeking a combination of robust cooling performance and a luxurious design, and easy installation and maintenance.

Practical Application of Wind Pipes-Associated Cold Machine Daikin 2 FGN 300 HY 1/RCN150HY19x2

2 FGN 300 HY 1 - application

The wind tunnel junction air-conditioning Daikin 2 FGN 300 HY 1/RCN150HY19x2 with a high-power and ceiling-hiding design is ideal for many practical applications in large spaces where efficient and aesthetically pleasing cooling is required. Here are some practical applications of this product:

  1. Offices and Tall Buildings:

    • With a capacity of 30.000 BTU, the air-conditioning Daikin 2 FGN 300 HY 1/RCN150HY19x2 is capable of rapid and efficient cooling of office or high-rise building spaces. The ceiling-hiding design saves space and creates a modern, professional work space without losing aesthetics.
  2. Hotel and Tourist Area:

    • Hotels and resorts with large conference rooms or guest rooms may use a wind-pipe-connected air-conditioning system Daikin to ensure air conditioning efficiency for a large number of customers, providing maximum comfort.
  3. Restaurants and Cafés:

    • This air conditioner is also well-suited to large-size restaurants and cafés, which require quick and uniform cooling. The product helps maintain a cool and comfortable space for customers during the course of eating.
  4. Supermarkets and Trade Centers:

    • With refrigeration capabilities for large spaces, airconditioning Daikin 2 FGN 300 HY 1/RCN150HY19x2 is the ideal choice for supermarkets, department stores, or retail outlets, where steady temperatures need to be maintained to provide comfort to customers and preserve goods.
  5. Luxury residential and Sectai:

    • Large villas or high-end residential houses can also take advantage of this product to cool the entire space without reducing the aesthetics of the interior. Hiding the air-conditioning system ceiling makes the space more open and modern.

Air-pipe-connected air-conditioning Daikin 2 FGN 300 HY 1/RCN150HY19x2 not only offers superior cooling efficiency but also is an ideal solution for aesthetically demanding, space-efficient and easily installed spaces.

Detailed Instructions for Installation and Operation of Air-Tube Connecting Units Daikin 2 FGN 300 HY 1/RCN150HY19x2

The following is a detailed guide to the installation and operation of a windguide-connected air conditioner Daikin 2 FGN 300 HY 1/RCN150HY19x2. The installation process requires a professional technician to ensure operational efficiency and safety.

I. Installation of the Air-Tube Coupler Daikin 2 FGN 300 HY 1/RCN150HY19x2

  1. Location preparation for installation:
    • Select Installation Location: Choose a suitable hiding spot for indoor unit, so that the surrounding space is large enough for installation and maintenance. Make sure indoor unit is installed in an open, free-of-impact area.
    • Check ceiling texture: Make sure the ceiling is sturdy enough to support the weight of indoor unit and the supporting parts.
    • Position outdoor unit: outdoor unit should be installed outdoors, away from polluted air, dirt, and direct sunlight.
  2. Installation indoor unit (Indoor Unit):
    • The installation position indoor unit is measured and marked. indoor unit should be installed at least 5 cm from the ceiling for easy installation and maintenance.
    • Insert the indoor unit mount into the prepared position.
    • Connection of co-piping (inlet and outlet gas pipes) to indoor unit. Ensure tight connection without leakage.
  3. Installation outdoor unit (Outdoor Unit):
    • Outdoor unit should be placed in a well - ventilated area with minimal dust and no obstructions to block airflow.
    • Ensure outdoor unit is not exposed to direct heat or sunlight sources.
    • Connect the gas pipes, electrical wires, and drainage system from indoor unit to outdoor unit. Install the drainage pipeline from indoor unit to the building's drainage system.
  4. Wind tunnel installation:
    • Connect the wind tunnel system from indoor unit to the areas to be cooled. Make sure the wind tunnel is firmly installed and there is no leakage.
    • Use the appropriate wind tunnel fittings to ensure that cool air is evenly distributed throughout the room.
  5. Electrical connections:
    • Connecting electrical wires between indoor unit and outdoor unit, ensuring proper electrical safety regulations.
    • Make sure all connections are secure and fireproof.
  6. System Testing:
    • Double check the connections of copper pipes, electrical wires, and wind pipes to make sure there are no leaks.
    • Load gas R410A into the system if necessary, ensuring proper gas pressure.

II. Operation of Air-Flow Coupler Daikin 2 FGN 300 HY 1/RCN150HY19x2

  1. Machine Start:
    • Turn on the power and open the remote or the top panel indoor unit.
    • Select the Cooling Mode and adjust your desired temperature.
    • Make sure the windows are not hidden so that air can circulate easily.
  2. Temperature and Mode of Operation:
    • Temperature tuning is required, with ideal temperature ranges from 24 -26°C.
    • The air conditioner will automatically adjust fan speed and airflow based on your selected cooling setting.
    • Check the coldness and make sure indoor unit works properly.
  3. Operating Other Functions:
    • Fan Mode: This mode uses only fans without refrigeration, and is suitable for air circulation.
    • Dry Mode: Helps reduce air humidity without lowering the temperature too much.
    • Auto Mode: The cooler will automatically adjust its cooling parameters to your current room temperature.
  4. Periodic Maintenance:
    • Clean air filters periodically to ensure optimal cooling performance and extend the life of your machine.
    • Check your wind tunnel system to make sure it is not clogged.
    • Periodically maintain outdoor unit and indoor unit, check the amount of cold gas and re-charge if necessary.

III. Important Considerations

  • Electrical safety: Make sure all electrical connections are properly made and check the circuit breakers to protect your machine.
  • Installation Space: Make sure there is enough room around the air conditioner to allow for air circulation.
  • Energy Saving Mode: If so, use energy - saving mode to reduce your electricity bills.

Proper installation and operation will help the air-conditioning Daikin 2 FGN 300 HY 1/RCN150HY19x2 to function efficiently, providing a cool and comfortable space for the user.