VRV Air Conditioning Joint Stock CompanyCEO@vrv.com.vn

Packaged DAIKIN

2FGN250HY1

Product code: 2 FGN 250 HY 1

Contact

Technical specifications Daikin Chen 1-way cooling-only 2FGN250HY1/RCN125HY19x2

  • Manufacturer: Daikin
  • Type of machine: 1-way cooling-only (cooling only)
  • Capacity: 25.000 BTU (Efficient Cooling for Large Space)
  • Feature Inverter: None
  • Refrigerant: R410A (energy - saving and environmentally friendly)
  • Sound pressure level:
    • Indoor: 32 dB (A) (low noise level, providing a quiet environment)
    • Outdoor: 55 dB(A)
  • Voltage: 220V / 50Hz
  • Size indoor unit (WxHxD): 1200 x 275 x 500 mm
  • Size outdoor unit (WxHxD): 880 x 700 x 330 mm
  • Weight indoor unit: 12 kg
  • Weight outdoor unit: 47 kg
  • Warranty:
    • 2 year for machine
    • 5 years for compressor
  • Origin: Malaysia

Original page prices at the date of copying 10/11/2026. Contact to confirm the current quotes.

PRODUCT DETAILS

Description & technical specifications

Wind Pipes-Keeping Cold Machine Daikin Ceiling Hiding 1-way cooling-only 2 FGN 250 HY 1/RCN125HY19x2 – Savings Cold Solution and Efficiency

2FGN250HY1

The air-pipe-packed Daikin ceiling-hidden 1-way cooling-only 2 FGN 250 HY 1/RCN125HY19x2 air-conditioner is an ideal choice for large spaces, offering rapid and uniform cooling. With a capacity of 25.000 BTU, this product makes air conditioning usable in spacious rooms, from offices and halls to modern living spaces.

Outstanding feature: 2 FGN 250 HY 1

  • Warranty: 2 year full machine and 5 year for compressor, ensuring long term quality and comfort with use.
  • Manufacturer: Daikin – brand known for its high - quality air conditioning products.
  • Type of machine: 1-way cooling-only – suitable for cooling in the summer.
  • Feature Inverter: No Inverter feature, suitable for simple refrigeration needs, does not require high power savings.
  • Origin: Malaysia – ensure product quality to international standards.
  • Type of gas used: R410A – an environmentally friendly gas that improves cooling efficiency.

The air-pipe-connected air conditioner Daikin 2 FGN 250 HY 1/RCN125HY19x2 not only provides cool air but also makes it easy to install and operate in a variety of different spaces. The product is a perfect choice for those seeking efficient and durable refrigeration solutions.

Practical Application of the Wind Pipes-Assisted Cold Machine Daikin Ceiling Hiding 1-way cooling-only 2 FGN 250 HY 1/RCN125HY19x2

2 FGN 250 HY 1 - Practical Application

The air-pipe-packed Daikin ceiling-hiding 1-way cooling-only 2 FGN 250 HY 1/RCN125HY19x2 air-conditioner can be widely used in a variety of environments and spaces, owing to its neat ceiling-hiding feature and efficient refrigeration. Here are some common practical applications:

  1. Company's Office:

    • With a 25.000 BTU capacity, this air conditioner is well suited for large offices or shared work spaces. The wind-pipe connector system provides uniform cooling without noise, providing a quiet and comfortable working environment.
  2. The Grand Apartments and the Sejm:

    • The installation of a ceiling-hidden air conditioner saves space and brings high aesthetics to the room. The 25.000 BTU power is strong enough to cool spacious living rooms or bedrooms, ensuring the air stays cool during summer.
  3. Hotel and Resort:

    • Resort or hotel resorts can take advantage of this air conditioning to cool large rooms, corridors, or communal areas without losing the beauty of the space. The air conditioning hide ceiling system helps to create a luxurious space and is not disrupted by traditional indoor unit areas.
  4. Commercial Buildings:

    • Ducted wiring provides efficient and uniform cooling of floors in high-rise buildings, especially commercial centers, offices, or halls, which are large in area and require powerful but noiseless cooling systems.
  5. Restaurants, cafes?

    • Dining spaces need an effective cooling system to ensure comfort for the customer. A ventilation tube-packed Daikin concealed ceiling cooler helps maintain cool temperatures without compromising the interior design of the space.
  6. Conference and seminar rooms:

    • Conference and conference rooms require cool and quiet air, which facilitates meetings and discussions. The high-powered, ceiling-hidden air conditioner ensures uniform cooling of the vast space.

Featuring a ceiling-hiding feature, this air conditioner not only saves space but also creates a high aesthetic, suitable for buildings requiring modern and minimalist interior design.

Installation and Operation Guide for Wind Pipes-Assisted Cold Machine Daikin Ceiling Hiding 1-way cooling-only 2 FGN 250 HY 1/RCN125HY19x2

1 Installation Instructions:

Preparation:

  • Installation Location indoor unit: Choose the location of the ceiling for installation indoor unit, ensuring that the installation space is large enough and free of obstructions. indoor unit Should be hidden in the plaster ceiling for aesthetic enhancement.
  • Position outdoor unit: Make sure the outdoor installation site outdoor unit has a well-ventilated space, avoiding any obstruction or obstruction of the wind. outdoor unit should be located in a place where heat escape and maintenance are easy to maintain.

Step 1: Assemble indoor unit

  • Wind pipe connection: Install the wind tunnel in the intake and exhaust ports of indoor unit. Use the right size and material wind tunnel to ensure optimal cooling efficiency.
  • Attach indoor unit to the ceiling: Insert the indoor unit into a drywall ceiling or steel frame, using specialized screws to ensure stability and no vibrations.

Step 2: Assemble outdoor unit

  • Outdoor Installation outdoor unit: Place outdoor unit in a well-ventilated area, avoiding wind-shielding. If installed on a roof or concrete support, use a sturdy support to immobilize outdoor unit.
  • Connecting gas pipes and electrical wires: Connecting the gas pipe (R410A) and the electrical wires from indoor unit to outdoor unit. Ensuring that all connections are tightly screwed and there is no leakage.

Step 3: Test for Gas Leakage

  • Gas leak check: After the connection is complete, use a gas leak tester to ensure there are no leaks in the system.

Step 4: Power Source

  • Electrical Connection: Connecting power source from grid to air conditioner in accordance with technical specifications. Ensuring the power system has overload protection and safety assurance.

2. Operation Instructions:

Step 1: Start Machine

  • Power up: Turn on the air conditioner and control system with an electrical switch. If you have a remote, check the battery and make sure the device can receive the signal.
  • Select the cooling mode: Use the remote or console of your console to select a cooling mode. Mode 1-way cooling-only is cooling only, with no heating function.
  • Temperature Adjustments: Set the desired temperature, typically from 20 -25°C as the ideal temperature level for indoor spaces.
  • Adjust fan speed: Adjust the fan speed depending on the space and whether you want to cool it quickly or slowly.

Step 2: Test and Adjust

  • Check the wind: Ensure that the wind flow from the wind tunnel is distributed evenly throughout the space. If necessary, adjust the wind direction of indoor unit to direct into areas where cooling is required.
  • Noise Check: Refrigerators with Daikin cover typically operate at low noise, but if there is unusual noise, re-check the connections and make sure the air conditioner is firmly installed.

Step 3: Maintenance and Long - Term Operation

  • Periodic maintenance: Perform regular 6 month/month maintenance to ensure optimal cooling performance. Check filters, air duct systems, and gas status to avoid gas leakage.
  • Clean filters: Clean the air filters to ensure fresh air and minimize buildup of clogging dust.
  • Performance Check: Periodically check the cooling performance of the cooling system to promptly detect any failure and avoid energy loss.

Important Considerations:

  • Avoid placing obstructions near the wind tunnel, which can reduce cooling efficiency.
  • Make sure the space around outdoor unit is not obscured to keep the machine running efficiently.
  • Use the correct amount of power to avoid overloading and extending the life of your machine.

Conclusion:

The installation and operation of a ceiling-mounted Daikin air-conditioner 1-way cooling-only 2 FGN 250 HY 1/RCN125HY19x2 requires meticulous technique and preparation. Always follow the instructions to ensure long-term use and avoid undesirable breakdowns.