VRV Air Conditioning Joint Stock CompanyCEO@vrv.com.vn

Chiller DAIKIN

EWWH940VZSS

Product code: EWWH940VZSS

Contact

Technical specifications: EWWH940VZSS

  • Cooling capacity: 941KW (Cooling)
  • COP: 5.00W/W
  • Power Consumption: 188KW (Cooling)
  • Cooling/Max Start Line: 287/402 A
  • Number compressor: 2 The
  • The amount refrigerant R1234(ze)/7: 230kg
  • Chilled-water flow rate evaporator: 45 l/s
  • Cooling-water flow rate condenser: 54.9 l/s
  • Noise: 106 dB(A)
  • Machine size (H × W × L): 2,296 × 1,487 × 4,792 mm
  • Net weight/Operating weight: 5,590 × 6,220Kg

Original page prices at the date of copying 10/11/2026. Contact to confirm the current quotes.

Category: Chiller DAIKIN

PRODUCT DETAILS

Description & technical specifications

Cold Machine Chiller Daikin Model EWWH940VZSS: High Productivity, Energy Savings

EWWH940VZSS

The Chiller Daikin Model EWWH940VZSS air conditioner is an excellent solution for industrial buildings, office buildings, and commercial facilities that require high cooling demands. With cooling capacity up to 941KW, this air conditioner provides outstanding cooling performance in large spaces. Here are the salient features of this product:

1. Cooling capacity Strong EWWH940VZSS

With cooling capacity up to 941KW, the Cold Machine Chiller Daikin EWWH940VZSS is capable of efficient cooling for large air conditioning systems. The cooling capacity minimum reaches only 10%, which saves energy when excessive cooling is not required.

2. Efficiency COP High EWWH940VZSS

This air conditioner possesses COP (energy efficiency factor) up to 5.00 W/W, which provides excellent power efficiency. This helps to minimize operating costs and energy savings throughout its life.

3. Power source and power input

Power - powered machine 3 pha 400V/50Hz, which allows for stable and efficient operation. The power consumption of the machine is only 188KWminimize impact on the enterprise's electricity bill.

4. EWWH940VZSS Easy Management and Execution

With a maximum cooling start line of 402 A and a compressor system consisting of 2 units, this air conditioner ensures stable, durable operation. Besides, the 106 dB(A) noise of the unit is also controlled to minimize the impact on the surrounding environment.

5. Ruler size and Weight EWWH940VZSS

The cold machine Chiller Daikin EWWH940VZSS is large, with height 2,296 mm, width 1,487 mm, and length 4,792 mm, which are suitable for large space. The net weight of the machine is 5,590 kg and the operational weight is 6,220 kg, which is easy to transport and install.

6. Water flow and connection

The machine has chilled-water flow rate evaporator up to 45 l/s and cooling-water flow rate condenser as 54.9 l/s, which enhances refrigeration and maintains a stable temperature. Dimensions connection pipe evaporator and condenser are 219.1mm and 168.3mm, respectively, and are easily connected to the refrigeration system.

7. Refrigerant Play EWWH940VZSS

Machine use refrigerant R1234(ze), with amounts of refrigerant up to 230kg, ensures optimal and environmentally friendly cooling performance.

Why Choose Cold Machine Chiller Daikin EWWH940VZSS?

Cold machines Chiller Daikin EWWH940VZSS offer many benefits such as high cooling efficiency, energy savings, and ease of operation. They are ideal options for buildings, factories, and structures with large cooling requirements. With their high durability and cost-effectiveness, these products deserve to be a reliable cooling solution for all structures.

Technical specifications: EWWH940VZSS

  • Cooling capacity: 941KW (Cooling)
  • COP: 5.00W/W
  • Power Consumption: 188KW (Cooling)
  • Cooling/Max Start Line: 287/402 A
  • Number compressor: 2 The
  • The amount refrigerant R1234(ze)/7: 230kg
  • Chilled-water flow rate evaporator: 45 l/s
  • Cooling-water flow rate condenser: 54.9 l/s
  • Noise: 106 dB(A)
  • Machine size (H × W × L): 2,296 × 1,487 × 4,792 mm
  • Net weight/Operating weight: 5,590 × 6,220Kg

Select the Cold Machine Chiller Daikin EWWH940VZSS to enjoy superior cooling performance and cost - saving for your business!

Practical Application of Cold Machines Chiller Daikin EWWH940VZSS

The Chiller Daikin Model EWWH940VZSS Cold Machine is not only a conventional cooling device but also widely used in various fields due to its robust capacity and energy-efficient performance. Here are the practical applications of this product:

1. System air conditioning for Tall Buildings

For cooling capacity up to 941KW, the chiller Daikin EWWH940VZSS air-conditioning is ideal for air conditioning systems in high-rise, office and condominium buildings. This system is capable of uniform cooling of large areas, keeping the space comfortable and cool.

2. Factory Coolant Systems

In a factory environment, temperatures are frequently high due to constantly operating equipment and machinery. Air conditioning chiller Daikin EWWH940VZSS helps control the temperature in factory buildings, protects equipment and machinery from overheating, while ensuring comfortable working conditions for workers.

3. Medical Applications

Hospitals, laboratories, and other healthcare facilities require a stable cooling system to protect medical equipment and medications and provide a comfortable environment for patients. Airconditioning chiller Daikin EWWH940VZSS can provide continuous and efficient cooling in healthcare facilities, ensuring an optimal working environment.

4. Data Center Coolant System

Data centers require precise temperature control to protect critical servers and devices from overheating. The chiller Daikin EWWH940VZSS refrigerator can meet the continuous and stable cooling requirements for data centers with robust cooling capacity and energy-saving performance.

5. The Center for Commerce Coolant System

Shopping centers, supermarkets, and retail areas with large spaces need efficient cooling systems to create comfortable shopping spaces for customers. Airconditioning chiller Daikin EWWH940VZSS can meet the need for large-scale cooling, which helps maintain the ideal temperature for the shopping space.

6. Applications in Big Buildings

This unit is also used in large construction projects such as airports, commercial complexes, conferences, or large outdoor events. For projects that require long periods of cooling and large areas, the chiller Daikin EWWH940VZSS unit is an ideal choice owing to its high capacity and durability.

Installation and Operation Guide for Cold Machine Chiller Daikin Model EWWH940VZSS

The air conditioner chiller Daikin EWWH940VZSS is a complex industrial device that requires proper installation and operation to ensure operational efficiency and safety. Here are detailed installation and operation instructions for this air conditioner.

I. Cold Machine Installation Instructions Chiller Daikin EWWH940VZSS

  1. Installation Area Preparation
    • Choose a good placement and make sure there is enough space around the air conditioner to allow for easy access and maintenance.
    • Make sure the floor is firmly installed, free of vibrations, and able to support the weight of the machine (5,590 kg net weight).
    • Make sure the space is well ventilated and free from obstructions or flammable materials.
  2. Basic Installation Work
    • Cold Water Pipe and Solvent Water Connection: Install cold water pipes for evaporator (45 l/s) and cooling water pipes for condenser (54.9 l/s). Size connection pipe evaporator is 219.1mm and condenser is 168.3mm.
    • Power Connection: Make sure to connect the 3 phase (400 V/50 Hz) power supply to the appropriate cables, and check the safety of the power system before starting your computer.
    • Reconnection refrigerant Clean: Install conduits for refrigerant R1234(ze) and ensure that refrigerant is fully loaded (230kg).
    • Lắp compressor: Machines with 2 compressor, need to be sure that they are properly connected and have the proper protection system.
  3. Pre-Operation Testing
    • Check the connections between the cold water and cooling water to make sure there are no leaks.
    • Check your electrical connections and controls to ensure they are working properly.
    • Check the coolant level refrigerant and make sure there is no shortage.

II. Cold Machine Operation Guide Chiller Daikin EWWH940VZSS

  1. Start Machine
    • Before starting your air conditioner, make sure that all your electrical, water, and refrigerant systems are properly connected and check them thoroughly.
    • Turn on the power and check the indicators on the dashboard.
    • Start compressor and check the pressure refrigerant. If compressor is functioning normally, the system will begin cooling.
  2. Temperature Controls and Control Systems
    • Set the temperature you need to cool down on the cooling system.
    • Check the operating settings such as cooling or maintaining a constant temperature and adjusting as required.
  3. Monitor the Operations
    • Keep track of things like start - up, power input power, chilled-water flow rate heat and water to ensure that your machine is running properly.
    • Check the noise level of the machine (106 dB(A)) to make sure that it does not disturb the surrounding environment.
    • Make sure your computer is working properly during use.
  4. Maintenance and Periodic Inspection
    • Clean filters and check components such as compressor, evaporator, and condensers periodically to maintain optimal performance.
    • Levels Check refrigerant Cool down and refill if necessary.
    • Check the power supply to make sure there are no issues with the power supply.
  5. Shutdown
    • When no machine is needed, shut down the machine through the console and ensure that all systems are safely disconnected.
    • Make sure to turn off the power and drain the system if it needs long - term maintenance.

III. NOTES FOR OPERATION

  • Electrical Safety: Make sure that the entire power system is connected properly, using electrical protection devices such as circuit breakers, fuses, and circuit breakers.
  • Regular Checkup: Regularly check the operating indicators of the machine to detect and promptly deal with problems such as leakage, failure, or unstable cooling performance.
  • Pay Attention to Noise: The noise level of the machine is quite high (106 dB(A)), so it is recommended that the machine be installed in appropriate areas or soundproofing measures be used if necessary.

Conclusion

The installation and operation of air conditioning chiller Daikin EWWH940VZSS requires adherence to technical manual steps to ensure cooling efficiency and durability. Regular maintenance and monitoring of the operation process are critical to keep the system running stably and energy efficient.